Error Code: EH 0b – Indoor Main Board and Display Board Communication Error

Modified on Fri, 23 May at 1:20 PM

Error Code: EH 0b – Indoor Main Board and Display Board Communication Error
Applies to LETO and AURA Series


What this means:
The main control board (indoor PCB) isn’t receiving signals from the display board. This usually means there’s a wiring issue, a faulty display board, or a failure on the main PCB.


Try this first (easy fix):

  1. Turn off power to your mini split completely.

  2. Wait 2 full minutes.

  3. Turn the power back on and check the display.

  • If the error is gone — the system is working normally.

  • If the error stays — move to the next step.


Next steps (for technicians):

  • Check the communication cable between the display board and indoor PCB.

  • Ensure all connections are secure and not damaged.

  • If wiring is fine:

    • Try replacing the display board.

    • If the error still shows after that, replace the indoor main PCB.


What you might need:

  • Display board

  • Indoor PCB

  • Communication wire


Helpful tip:
Loose connectors or damaged wires are the most common cause of this error. Always start with a wiring check before replacing any components.