Senville AURA Series Error Code Reference Guide

Modified on Mon, 7 Apr at 10:32 AM

About This Guide

This article provides a complete list of error codes that may appear on Senville mini split indoor units. These codes help identify problems with sensors, communication, refrigerant, or other electrical components. Use the information below to troubleshoot or report issues.


Normal System Messages (Not Errors)

CodeDescriptionSolution
dFDefrostNo action required — normal cycle
CLFilter cleaning reminder / Active cleanClean filters (displays 15 seconds after power-on)
F (some models)Filter replacement reminderReplace filters if applicable
FPHeating mode in room temp under 8°CNo action required — automatic heating safeguard
FCForced coolingCheck if cooling was manually forced (e.g., by remote or setup)
APWi-Fi AP modeSystem is in Wi-Fi pairing mode — proceed via Alexa app
CPRemote control switched offRestart unit using remote or power cycle

Indoor Unit Error Codes

CodeIssueSolution
EH 00Indoor EEPROM malfunctionReplace indoor main PCB (TS01-IDU)
EH 0AIndoor EEPROM parameter errorReprogram or replace indoor PCB (TS01-IDU)
EL 01Indoor & outdoor communication errorCheck wiring and connectors; replace PCB if needed (TS02-S-INV)
EH 02Zero-crossing signal detection errorReplace indoor main board (TS03)
EH 03Indoor fan speed out of controlCheck fan motor and control board (TS04-S-IDU)
EH 60Room temperature sensor (T1) errorReplace T1 sensor (TS05-IDU)
EH 61Pipe temperature sensor (T2) errorReplace T2 sensor (TS05-IDU)
EH 0Display board and control board communication errorCheck or replace one or both boards (TS07)
FH CCRefrigerant sensor errorReplace sensor module (TS05-N10)
EH C1Refrigerant leak detectedCheck for refrigerant leaks and sensor (TS06-N10)
EH C2Sensor out of range and leak detectedReplace sensor and inspect refrigerant line (TS06-N10)
EH C3Sensor out of rangeReplace refrigerant sensor (TS05-N10)
EC C1Other indoor unit leak (multi-zone)Leak inspection and sensor replacement (TS06-N10)

Outdoor Unit Error Codes

CodeIssueSolution
EC 51Outdoor EEPROM parameter errorReplace or reprogram outdoor board (TS01-ODU)
EC 52Coil temp. sensor (T3) errorReplace T3 sensor (TS05-ODU)
EC 53Ambient temp. sensor (T4) errorReplace T4 sensor (TS05-ODU)
EC 54Compressor discharge temp. sensor (TP) errorReplace TP sensor (TS05-ODU)
EC 56Indoor coil outlet temp. sensor (T2B) error (Multi-zone)Replace T2B sensor (TS05-ODU)
EC 07Outdoor fan speed out of controlInspect fan motor and drive circuit (TS04-ODU)
EL 0CSystem lacks refrigerantRecharge system and inspect for leaks (TS06-INV)

Protection and System Errors

CodeIssueSolution
PC 00IPM module protectionCheck cooling, IPM board (TS09-S)
PC 01Voltage protectionInspect input voltage (TS10-S)
PC 02Compressor/IPM over-temperatureInspect cooling, refrigerant flow (TS11-S-INV)
PC 04Inverter compressor drive errorReplace or test drive module (TS12-S)
PC 03Pressure protection (low/high)Verify pressure sensors and refrigerant levels (TS26-INV)
PC 0LLow ambient temp protectionNo action needed unless malfunctioning (LP)
----Multi-zone indoor units mode conflictEnsure all units are set to the same mode (TS14)

Other Notes

  • If the display shows a **garbled or undefined code**, ensure it’s not just showing a temperature.
  • Use the remote control to test the unit:
    • If it does not respond, the indoor PCB may need replacement.
    • If it does respond, the issue may lie with the display board.

Need More Help?

Still having trouble? Submit a support ticket and include the error code, model number, and what steps you’ve already tried. Our technical team is ready to assist you.

Helpful Resources

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article