Error Code: PC 00 – Outdoor IPM Module Protection

Modified on Thu, 22 May at 3:53 PM

Error Code: PC 00 – Outdoor IPM Module Protection


What this means:
This error occurs when the IPM (Intelligent Power Module) sends an abnormal voltage signal to the compressor drive chip. As a protection measure, the system shuts off to avoid damage.


Try this first (quick reset):

  1. Turn off power to the system completely.

  2. Wait 2 minutes.

  3. Turn the unit back on and observe the display.

  • If the error clears — the issue may have been temporary.

  • If the error remains — proceed with diagnostics.


Next steps (for technicians):

  1. Check the wiring between PCB and compressor:

    • If connections are loose or damaged → repair or replace wires and connectors.

  2. Check the IPM board:

    • If not functioning → replace the IPM module board or outdoor PCB.

  3. Check the outdoor fan and ventilation system:

    • If fan is not working or airflow is restricted → refer to “Fan Speed is Out of Control” diagnostics (e.g., EC 07).

  4. Test the compressor resistance:

    • If resistance is out of spec → replace the compressor.

    • If resistance is normal → replace the outdoor PCB.


What you might need:

  • IPM module board

  • Outdoor PCB

  • Compressor

  • Outdoor fan assembly

  • Connection wires


Helpful tip:
Always begin with simple checks: wiring and fan function. Replacing the IPM or compressor should be the final step after verifying all other components.


Click here to view the detailed guide.TS26