Error Code: PC 00 – Outdoor IPM Module Protection
What this means:
This error occurs when the IPM (Intelligent Power Module) sends an abnormal voltage signal to the compressor drive chip. As a protection measure, the system shuts off to avoid damage.
Try this first (quick reset):
Turn off power to the system completely.
Wait 2 minutes.
Turn the unit back on and observe the display.
If the error clears — the issue may have been temporary.
If the error remains — proceed with diagnostics.
Next steps (for technicians):
Check the wiring between PCB and compressor:
If connections are loose or damaged → repair or replace wires and connectors.
Check the IPM board:
If not functioning → replace the IPM module board or outdoor PCB.
Check the outdoor fan and ventilation system:
If fan is not working or airflow is restricted → refer to “Fan Speed is Out of Control” diagnostics (e.g., EC 07).
Test the compressor resistance:
If resistance is out of spec → replace the compressor.
If resistance is normal → replace the outdoor PCB.
What you might need:
IPM module board
Outdoor PCB
Compressor
Outdoor fan assembly
Connection wires
Helpful tip:
Always begin with simple checks: wiring and fan function. Replacing the IPM or compressor should be the final step after verifying all other components.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article