Error Code: EL 16 – Communication Malfunction Between Adapter Board and Outdoor Main Board

Modified on Thu, 22 May at 3:52 PM

Error Code: EL 16 – Communication Malfunction Between Adapter Board and Outdoor Main Board


What this means:
The adapter PCB cannot detect the outdoor main control board. This usually indicates a wiring fault, board failure, or poor connection between the adapter and main PCBTS40.


Try this first (quick reset):

  1. Turn off power to the system.

  2. Wait at least 3 minutes.

  3. Restart the unit and observe if the error clears.

  • If the error clears — the system is operating normally.

  • If the error returns — proceed with the following diagnostics.


Next steps (for technicians):

  1. Check the wiring and connections:

    • Ensure all connection wires between the adapter board and outdoor main PCB are secure and properly inserted.

  2. Are all connections good?

    • If NO → fix or replace the connection wires.

    • If YES → continue.

  3. Replace the adapter PCB

    • If communication is still not restored → replace the adapter board.

  4. If issue persists after adapter replacement:

    • Replace the outdoor main PCB.


What you might need:

  • Connection wires

  • Adapter PCB

  • Outdoor main PCB


Helpful tip:
Most EL 16 issues stem from poor or reversed wiring. Always check physical connections before replacing boards.


Click here to view the detailed guide.TS40