Error Code: PC 40 – Communication Error Between Outdoor Main Chip and Compressor Driven Chip

Modified on Thu, 22 May at 3:49 PM

Error Code: PC 40 – Communication Error Between Outdoor Main Chip and Compressor Driven Chip


What this means:
The main control board in the outdoor unit cannot detect or communicate with the IPM (Intelligent Power Module)board. This failure interrupts the system's ability to control the compressor, triggering a communication faultTS26.


Try this first (quick reset):

  1. Power off the unit completely.

  2. Wait 2 full minutes.

  3. Turn it back on and observe the error status.

  • If the error clears — communication may have recovered.

  • If it returns — proceed with diagnostics.


Next steps (for technicians):

  1. Check for LED indicator on the IPM board:

    • If no LED is lit → proceed to inspect the signal path.

  2. Inspect the signal wire between IPM board and outdoor main board:

    • If not connected or damaged → reconnect or replace the wire.

  3. Reconnect and retry:

    • If the error persists → replace the IPM board.

  4. If error continues after IPM board replacement:

    • Replace the electric control box.

  5. If still unresolved:

    • Replace the outdoor main control board.


What you might need:

  • Signal connection wires

  • IPM module board

  • Outdoor main PCB

  • Electric control box


Helpful tip:
LED indicators on the IPM board can quickly confirm whether power and communication are active. Start with this visual check before replacing components.


Click here to view the detailed guide.TS26