Error Code: EH 0A – Indoor EEPROM Parameter Error
What this means:
This error means that the indoor unit’s main control chip cannot read its EEPROM — the memory chip that holds key configuration data. This prevents the system from operating normallyTS19.
Try this first (quick reset):
Turn off the power supply completely.
Wait 2 minutes.
Turn it back on and check if the error clears.
If the error disappears — the system is functioning normally.
If it remains — the EEPROM is not responding, and the board must be replaced.
Next steps (for technicians):
Replace the indoor main PCB.
What you might need:
Indoor PCB
Helpful tip:
The EEPROM chip is a permanent memory module that stores critical system information. When it fails, replacing the entire PCB is the only solution — it cannot be serviced independently.