Error Code: EC 51 – Outdoor EEPROM Parameter Error

Modified on Thu, 22 May at 3:45 PM

Error Code: EC 51 – Outdoor EEPROM Parameter Error


What this means:
The system’s main control chip (indoor or outdoor PCB) is not receiving proper feedback from the EEPROM chip — a memory component that stores essential configuration data. This causes the system to shut down or fail to start properly.


Try this first (quick reset):

  1. Turn off the power to the system completely.

  2. Wait 2 full minutes.

  3. Turn the system back on and check if the error clears.

  • If the error clears — the system is now operating normally.

  • If the error remains — continue below.


Next steps (for technicians):

  • Replace the outdoor main PCB.

  • In rare cases, if the issue persists after PCB replacement, inspect or replace the indoor PCB as well.


What you might need:

  • Outdoor PCB

  • Indoor PCB (only if outdoor PCB replacement does not resolve the issue)


Helpful tip:
The EEPROM chip is a reprogrammable memory component critical for the system’s startup. If it fails or cannot be read, replacing the entire board is the only solution.


Click here to view the detailed guide.TS12