Multi-zone systems: compatible indoor units, how many, and mixing types

Modified on Thu, 26 Nov at 12:09 PM

Short answer: a Senville multi-zone outdoor unit supports 2 to 6 indoor units, depending on its size. You can mix wall-mounted, cassette, ducted and floor units, as long as each one is multi-zone compatible and you stay within the BTU and line length limits.

How many indoor units can I connect?

Outdoor unitIndoor units (ports)Pre-charged for (total line)Max. line per indoor unitApprox. capacity, cooling / heating
18,000 BTU (18HF-MOA)Up to 375 ft98.4 ft28,000 / 27,000 BTU
28,000 BTU (28HF-MOA)Up to 4100 ft114.8 ft37,000 / 36,000 BTU
36,000 BTU (36HF-MOA)Up to 5125 ft114.8 ft43,000 / 44,000 BTU
48,000 BTU (48HF-MOA)Up to 6150 ft114.8 ft57,000 / 57,000 BTU

Longer total line runs need extra refrigerant, added by a licensed HVAC technician.

Why can I connect more indoor BTUs than the outdoor unit's size?

Rooms rarely need full heating or cooling at the same time. The outdoor unit adjusts its output to the demand, so the combined size of the indoor units can be higher than the outdoor unit's rating.

Which indoor units are multi-zone compatible?

Multi-zone compatibleSingle-zone only (not for multi-zone)
SENA-06HF-IAASENA-06HF-IGG
SENA-09HF-IAASENA-09HF-IGG
SENA-12HF-IAASENA-12HF-IGG
SENA-18HF-IAASENA-18HF-IGG
SENA-24HF-IAA
SENA-24HF-IGG
SENA-33HF-IGG

Important for older systems: the indoor units above are for Senville's current MOA multi-zone outdoor units, which use R454B refrigerant. They are not compatible with older MOZ multi-zone outdoor units (for example SENA-30HF-MOZ), which use R410A. The indoor units for a MOZ system are the IZ and IY models, which are not currently in stock. If you have a MOZ outdoor unit, please contact Technical Support at support@senville.com or 1-800-242-4935 (option 3) before ordering an indoor unit.

Ceiling cassette, concealed duct and floor units can be mixed with wall-mounted units. See wall mount, cassette, duct and floor unit model numbers.

Good to know

  • All indoor units must run in the same mode. If one is set to COOL and another to HEAT, the display shows "--". See "--" mode conflict.
  • A single-zone system can't be converted to multi-zone. Single-zone outdoor units have only one port.
  • R410A and R454B units can't be mixed. See Are R410A and R454B units compatible?

Deciding between one multi-zone system and several single-zone units? See Should I buy a multi-zone system or several single-zone units? Want us to check a combination? Submit a request with the rooms and indoor units you have in mind.

You can also configure and verify your multi-zone combination using Senville’s Build Your Own tool: https://senville.com/mini-split-ac/multi-zone/build-your-own/
Short answer: a Senville multi-zone outdoor unit supports 2 to 6 indoor units, depending on its size. Multi-zone condensers require at least two indoor heads to be connected to operate; they cannot run with only one head.